19/11/2015 Vieux  
 
  56 ans, Liège
  jcoenen est connecté maintenant
Howdy from Belgium or dzień dobre !

Nice to see that the software made it abroad ...

Yes the install script is not yet compatible with Jessie, it took me by surprise that debian implemented systemd to replace initd on which the VMC server startup is based.

But fortunately for you we've solve that problem already.

For Jessie here it is

sudo nano /etc/systemd/system/VMCserver.service

[Unit]
Description=VMC python server
After=syslog.target network.target

[Service]
Type=simple
User=root
WorkingDirectory=/home/pi/raspVMC-master
ExecStart=/home/pi/raspVMC-master/server.py
StandardOutput=syslog
StandardError=syslog


Restart=always

[Install]
WantedBy=multi-user.target


Then

sudo systemctl start VMCserver

to activate it.

The same goes for fhem

sudo nano /etc/systemd/system/fhem.


[Unit]
Description=FHEM Perl Server
After=syslog.target network.target

[Service]
Type=forking
User=fhem
WorkingDirectory=/opt/fhem
ExecStart=/usr/bin/perl fhem.pl fhem.cfg


you may add to automatically restart when fhem dies but it's not indispensable.
Restart=always

[Install]
WantedBy=multi-user.target


then
sudo systemctl fhem start

starts it up.

Dernière modification par jcoenen 19/11/2015 à 14h49.
19/11/2015 Vieux  
 
  56 ans, Liège
  jcoenen est connecté maintenant
Citation:
Posté par listhor Voir le message
Hi All, greetings from Poland!



root@garaz:~# /home/pi/raspVMC-master/server.py
Traceback (most recent call last):
File "/home/pi/raspVMC-master/server.py", line 218, in <module>
CCserver.bind(CCserver_address)
File "/usr/lib/python2.7/socket.py", line 224, in meth
return getattr(self._sock,name)(*args)
socket.error: [Errno 98] Address already in usr

Does above mean that script has been already executed? If so, why there's no ttyVMC created? None of dedicated logfiles are created, except fhem logfile.
Indicates that the port for the CCEASE cannot be opened, it is actually missing from the VMC.ini config file sio it defaults to 10001, as you defined the server port to be on 10001 in the config file, it cannot open it, if you don't run webmin on port 10000 you can leave the server main port on it or use for example 10003 or define CCEASE on another port via the CCEASE section, as far as the 3 ports are different and not allocated to another process the SW will work.

[CCEASE] ; CCEASE/ComfoSense related informations
tty=/dev/ttyUSB2 ; address of the CCEASE/COMFOSENSE
port=10003 ; address of the dedicated port for CCEASE/COMFOSENSE


When you refer to the voltage of the VMC, normally TX should be powered (output) and RX (input) should be at ground level. But obviously TX of the VMC is RX of the CCEase.

Whatch out with the wiring of the 12 volts, this is only to power the Comfosense and should not be connected to the raspberry's interface.

Dernière modification par jcoenen 19/11/2015 à 14h51.

19/11/2015 Vieux  
 
  Autre pays
 
Bon jour! Comment çava?
That's all of my French language You and sjauquet did a great job developing that piece of software. I wrote a message to Zehnder asking for any kind of interface which allows LAN integration they may have on offer but they didn't even bother themselve to answer it...

I'm really impressed with such a prompt reply, thanks very much.
Just to keep everything clean & tidy, shall I remove entry in /etc/inittab?

For a time being I'm out of home and I can connect to my raspberry over VPN. Due to the fact it is connected to my LAN through Wi-Fi dongle I experience, from time to time, some connectivity issues. And now I need to ask my wife to pull out the plug, haha. It seems that after certain inactivity period, wi-fi connection dies out. Have you seen something like that?
Anyway as soon as it is back online I will apply changes.

Which port is used to connect external applications? Server port, 10001 in my case?
[server]
bind =
port = 10001

I want to use Fibaro virtual device to monitor and control StorkAir. Maybe I'll buy NetAtmo as well...
One last question, can I use socat to make another serial port - RS485 (will be connected to UPS and used for remote monitoring) visible over LAN?

Cheers!
19/11/2015 Vieux  
  France
 
Citation:
Posté par jcoenen Voir le message
Bonjour

Oui, certains utilisent la carte Luxe (je me souviens que le connecteur PC a été utilisé avec succès).

LudoH par example a une luxe et est opérationnel, mais il a du changer de convertisseur RS232/USb car celui initialement essayé renseignait RS232/TTL et était TTL (0-5Volts) alors que le RS232 requiert -3 V + 3 V !
Oups je ne comprends plus rien.
coté rpi: je suis en logique TTL 3v ?
coté VMC en rs232 +12V-12V ?
j'utilise ce composant
http://optimus.meleeisland.net/downl...ts/st232cn.pdf
il vous semble correct.
19/11/2015 Vieux  
 
  56 ans, Liège
  jcoenen est connecté maintenant
Citation:
Posté par listhor Voir le message
Bon jour! Comment çava?
That's all of my French language You and sjauquet did a great job developing that piece of software. I wrote a message to Zehnder asking for any kind of interface which allows LAN integration they may have on offer but they didn't even bother themselve to answer it...

Surprise surprise ...

I'm really impressed with such a prompt reply, thanks very much.
Just to keep everything clean & tidy, shall I remove entry in /etc/inittab?

You can keep it there it's only used by initd which is not active in Jessie and will never be ...

For a time being I'm out of home and I can connect to my raspberry over VPN. Due to the fact it is connected to my LAN through Wi-Fi dongle I experience, from time to time, some connectivity issues. And now I need to ask my wife to pull out the plug, haha. It seems that after certain inactivity period, wi-fi connection dies out. Have you seen something like that?

Yes I have the same issue, resolution is not to my taste though, the Wifi does not reconnect automatically if dropped, a solution is to run a script that pings something and restart the network interface when ping does not succeed ...

I recently also noticed that the default route drops out on the raspberry with Wifi, this is mainly annoying for when you want to connect from the outside world (thorugh the internet router), solution: same ugly one as above.

Anyway as soon as it is back online I will apply changes.

Which port is used to connect external applications? Server port, 10001 in my case?
[server]
bind =
port = 10001

Yes you wired port 10001 to the clients

I want to use Fibaro virtual device to monitor and control StorkAir. Maybe I'll buy NetAtmo as well...
One last question, can I use socat to make another serial port - RS485 (will be connected to UPS and used for remote monitoring) visible over LAN?

Fibaro, zWave, I have a zWave stick on my raspberry and drives the zWave stuff with FHEM. Monitor, I suppose like SebCbien you'd like to monitor the power used by the VMC ? If you haven't got any zwave device home, the fibaro central unit does not make a lot of sense, you'd be better off with fhem and the tablet UI display (it does look better then the default)

Cheers!
PS. I don't speak polish, just a few words (mainly bad ones) taught by friends

Dernière modification par jcoenen 19/11/2015 à 15h06.
19/11/2015 Vieux  
 
  Autre pays
 
Citation:
Posté par jcoenen Voir le message
Indicates that the port for the CCEASE cannot be opened, it is actually missing from the VMC.ini config file sio it defaults to 10001, as you defined the server port to be on 10001 in the config file, it cannot open it, if you don't run webmin on port 10000 you can leave the server main port on it or use for example 10003 or define CCEASE on another port via the CCEASE section, as far as the 3 ports are different and not allocated to another process the SW will work.

[CCEASE] ; CCEASE/ComfoSense related informations
tty=/dev/ttyUSB2 ; address of the CCEASE/COMFOSENSE
port=10003 ; address of the dedicated port for CCEASE/COMFOSENSE


When you refer to the voltage of the VMC, normally TX should be powered (output) and RX (input) should be at ground level. But obviously TX of the VMC is RX of the CCEase.

Whatch out with the wiring of the 12 volts, this is only to power the Comfosense and should not be connected to the raspberry's interface.
Thanks for that, that's what I thought so.
And in general, once I get everything up and running and connected to Fibaro HC2 I'm going to write a brief tutorial on http://forum.fibaro.com/index.php?/t...foair-zehnder/
to spread good news over the world.
19/11/2015 Vieux  
 
  56 ans, Liège
  jcoenen est connecté maintenant
Citation:
Posté par listhor Voir le message
Thanks for that, that's what I thought so.
And in general, once I get everything up and running and connected to Fibaro HC2 I'm going to write a brief tutorial on http://forum.fibaro.com/index.php?/t...foair-zehnder/
to spread good news over the world.

Cool, I should put up a page somewhere for the users to post their installation ...

And thanks for reminding me that I need to write some pages up to document the thnigie

By the way, in the protocol there is a command to switch control to PC/CCEase, I haven't got the luxe version so on my VMC nothing happens when I change that value, maybe it controls the ports on the luxe card ???

Dernière modification par jcoenen 19/11/2015 à 15h12.
19/11/2015 Vieux  
 
  Autre pays
 
Regarding Zwave, so far, I have 60+ devices installed at home and for VMC and UPS purpose I'm going to buy the second greenwave powernode - it's cheaper than 2x Fibaro wall plugs and you have 6 outlets.
Plan is to find or "develop" video gate and based on weather station (NetAtmo or maybe something based on raspPi) integrate garden watering - solenoids controlled by zwave switches.

Citation:
Yes I have the same issue, resolution is not to my taste though, the Wifi does not reconnect automatically if dropped, a soution is to run a script that pings something and restart the network interface when ping does not succeed ...
BTW, do you have such a script in possesion??
Ok, I demand too much. Once again, thank you very much!
19/11/2015 Vieux  
 
  Autre pays
 
Citation:
Posté par jcoenen Voir le message
Cool, I should put up a page somewhere for the users to post their installation ...

And thanks for reminding me that I need to write some pages up to document the thnigie

By the way, in the protocol there is a command to switch control to PC/CCEase, I haven't got the luxe version so on my VMC nothing happens when I change that value, maybe it controls the ports on the luxe card ???
I have CCEase connected. You are saying that this settings may permanently enable RS232 port on WHR950 unit?
Let me straight the things out:
Serial connection is from StorkAir/VMC unit to -> raspPi and further to -> CCease. Server on RaspPi queues all the requests from i.e. CCease and Fhem or Fibaro virtual device/client and sends them down to StorkAir/VMC, am I right?
I can call myself advanced user but unfortunately not a programmer. Therefore I can only try to amend existing scripts and not to create them.
Therefore I rely on smart guys like you

One more thing, some more info about VMC units: http://zehnderamerica.com/installation-user-manuals/ Maybe you haven't seen this...

Dernière modification par listhor 19/11/2015 à 15h32.
19/11/2015 Vieux  
 
  56 ans, Liège
  jcoenen est connecté maintenant
Citation:
Posté par listhor Voir le message
Regarding Zwave, so far, I have 60+ devices installed at home and for VMC and UPS purpose I'm going to buy the second greenwave powernode - it's cheaper than 2x Fibaro wall plugs and you have 6 outlets.
Plan is to find or "develop" video gate and based on weather station (NetAtmo or maybe something based on raspPi) integrate garden watering - solenoids controlled by zwave switches.


BTW, do you have such a script in possesion??
Ok, I demand too much. Once again, thank you very much!
Heck it doesn't cost anything to ask, yes I do somewhere on the Wifi based machine, I'll see to it, and post it here.
19/11/2015 Vieux  
 
  56 ans, Liège
  jcoenen est connecté maintenant
Citation:
Posté par listhor Voir le message
I have CCEase connected. You are saying that this settings may permanently enable RS232 port on WHR950 unit?

Yes but it's pure speculation (in other words I may be completely wrong on that one).

Let me straight the things out:
Serial connection is from StorkAir/VMC unit to -> raspPi and further to -> CCease. Server on RaspPi queues all the requests from i.e. CCease and Fhem or Fibaro virtual device/client and sends them down to StorkAir/VMC, am I right?

You've got it right absolutely !

One more thing, some more info about VMC units: http://zehnderamerica.com/installation-user-manuals/ Maybe you haven't seen this...



I'll check them out, thanks.
19/11/2015 Vieux  
 
  Autre pays
 
Citation:
The same goes for fhem

sudo nano /etc/systemd/system/fhem.


[Unit]
Description=FHEM Perl Server
After=syslog.target network.target

[Service]
Type=forking
User=fhem
WorkingDirectory=/opt/fhem
ExecStart=/usr/bin/perl fhem.pl fhem.cfg

you may add to automatically restart when fhem dies but it's not indispensable.
Restart=always

[Install]
WantedBy=multi-user.target

then
sudo systemctl fhem start

starts it up.
But Fhem starts up automatically on Jessie - installed via apt-get install so it does it by default...
19/11/2015 Vieux  
 
  56 ans, Liège
  jcoenen est connecté maintenant
Raspberry pi Wifi check

Got it from HERE

I found another script in python that looks good, but I haven't tested it, I will see to it next week or so and post the result.

These scripts can be a pain as they reset the Wifi and thus could potentially enter a loop that takes the connection up and down.
19/11/2015 Vieux  
 
  56 ans, Liège
  jcoenen est connecté maintenant
Citation:
Posté par listhor Voir le message
But Fhem starts up automatically on Jessie - installed via apt-get install so it does it by default...
Ah, that's good, they must have added the systemd script in the meantime, as last week it was not the case ...
19/11/2015 Vieux  
 
  Autre pays
 
Citation:
Citation:
Yes I have the same issue, resolution is not to my taste though, the Wifi does not reconnect automatically if dropped, a soution is to run a script that pings something and restart the network interface when ping does not succeed ...
BTW, do you have such a script in possesion??
Ok, I demand too much. Once again, thank you very much!
Could this https://raw.github.com/dweeber/WiFi_...ter/WiFi_Check be a solution??
19/11/2015 Vieux  
 
  56 ans, Liège
  jcoenen est connecté maintenant
Citation:
Posté par listhor Voir le message
yep that's the one I posted in the link above
19/11/2015 Vieux  
 
  Autre pays
 
Citation:
PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ COMMAND
1121 root 20 0 14080 8692 5456 R 100,0 1,2 41:40.33 server.py
Is such high load is normal?
19/11/2015 Vieux  
 
  56 ans, Liège
  jcoenen est connecté maintenant
Citation:
Posté par listhor Voir le message
Is such high load is normal?

Yes, the server constantly monitors the serial devices attached and takes whatever CPU available to do so (loop), but it does so at low priority so should another process need the CPU, it will relinquish it.

So although it show high load, it is actually load because it sits waiting for incoming messages.
20/11/2015 Vieux  
 
  Autre pays
 
Hi again,

I'd managed to connect to raspPi and added systemd script. I can execute/start it manually but after reboot it doesn't run automatically (no server.py running and ports aren't open).
Am I missing something?

BTW, I installed that Wi-Fi script and it seems it helps. I read that wicd also does the same job...
20/11/2015 Vieux  
 
  56 ans, Liège
  jcoenen est connecté maintenant
Citation:
Posté par listhor Voir le message
Hi again,

I'd managed to connect to raspPi and added systemd script. I can execute/start it manually but after reboot it doesn't run automatically (no server.py running and ports aren't open).
Am I missing something?

BTW, I installed that Wi-Fi script and it seems it helps. I read that wicd also does the same job...

Noted, I think we did something else, can't recall what, but I'll check
Page 41 sur 67 Première page - Résultats 1 à 20 sur 1 340 Page precedente 313940 41 424351 Page suivante Dernière page - Résultats 1 321 à 1 340 sur 1 340


A lire également sur BricoZone...
Zehnder ou Storkair / whr ou confoD ? Par chevy3600 dans Plomberie, +3 13/06/2016
Storkair ConfoD luxe et domotique Par sebcbien dans VMC, PAC, Clim, +12 21/10/2013
VMC storkair Par lombsss dans VMC, PAC, Clim, +1 25/01/2013
VMC storkair comfod 350 Par sam_bech dans VMC, PAC, Clim, +16 22/01/2013
Où acheter VMC DF Zehnder/Storkair ? Par Lapilux dans VMC, PAC, Clim, +4 26/03/2012


Forum Domotique : Voir ce forum, Nouveautés, Actifs, Sans rép
Tout BricoZone : Page de garde, Dernieres 24h

Photos au hasard
Voir toutes nos photos


Pas encore membre de BricoZone ?!
Attention Pour participer, poser une Question ou Répondre : inscrivez vous !
Ceci vous permettra également de recevoir un email lors des réponses.
Mais même si vous ne voulez rien écrire : vous pourrez surveiller les forums et leurs nouveaux messages, et obtenir une vue rapide de tous les nouveaux messages depuis votre dernière visite !
Tout ceci est évidemment gratuit et rapide.

Visitez aussi : BricoZone France, nos Blogs. On aime Astel, JardiZone et InternetVista.
 
Connexion!
Identifiant
Mot de passe

Inscription - Oublié ?

Annuaire Pro

illiCO travaux

Un seul interlocuteur pour tous vos devis de travaux de rénovation !


FT Chassis

Spécialiste des châssis PVC, bois et aluminium, portes et volets roulants.


DECOCHALET

Vente et placement d'abris de jardin, carports, garages, pergolas, boxes pour chevaux, ...


Tendance Habitat

Entreprise générale du bâtiment

Ajoutez votre société