24/01/2016 Vieux  
 
  56 ans, Liège
 
oui c'est standard
24/01/2016 Vieux  
 
  34 ans, Hainaut
 
J'ai vérifié, tout me semble correct.

Au niveau applicatif:

Niveau page HTML, j'ai une 404 et une 500.

Contrôler sa VMC StorkAir / ComfoAir / zehnder via sa domotique

Je n'ai aucun process socat avec "ps -ef | grep socat", rien non plus avec "ps -ef | grep server".

J'ai regardé pour des logs, mais il n'existe pas de fichier "/var/log/VMClog.log".

Par contre dans le fichier "/var/log/VMCerr.log", j'ai de nombreuses fois: "/bin/sh: 1: exec: /home/pi/raspVMC-master/server.py: not found" En effet le répertoire "/home/pi/raspVMC-master" n'existe pas...

Au niveau de l'installation physique:

Bon je suspecte aussi mon cable ethernet entre la VMC (grenier) et le raspberry (buanderie) que j'ai serti moi-même. Je vais le contrôler en l'utilisant entre le raspberry (grenier) et le routeur (buanderie); ça va me permettre devoir si il est déjà partiellement défaillant ou non car je ne pense pas que tout les fils soient utilisés dans le cas d'une utilisation + classique. En même temps, comme je déplace temporairement mon raspberry au grenier, il va être à côté de la VMC. J'en profite pour les connecter avec un cable ethernet serti en usine.

Résultat --> j'arrive à accéder en SSH à mon raspberry (il sait faire des curl sans problème), donc mon cable entre le raspberry et la buanderie (routeur donnant accès à mon réseau privatif dont internet), initialement utilisé entre la VMC et le raspberry fonctionne bien. C'est une chose en moins. Pour le reste, le résultat est le même.

Je devrais donc tester de point à point comme jcoenen me l'a conseillé avec le multimétre car temporairement mon raspberry est au grenier à côté de la VMC. Par contre j'ai bien compris le mécanisme de test mais pas de où à où. Un pince dans le DB9 et l'autre côté sur la VMC, car sur la mienne je ne pourrais pas glisser de pince à l'intérieur.

Sinon après cela, je peux mettre en doute aussi la carte d'extension RS232 du raspberry, ou encore la carte mère du raspberry...

Dernière modification par jipsie 24/01/2016 à 18h55.
24/01/2016 Vieux  
 
  56 ans, Liège
 
Bon il semblerait que ton installation ne soit pas "standart".

Ou se trouve le directory raspVMC ?

Normalement loggé sur pi, après le download et unzip, un directory /home/pi/raspVMC-master est créé avec tout les logiciels a l'intérieur.

Le server est démarré a partir de ce directory (définition dans /etc/inittab), si tu as mis les logiciels ailleurs alors il faut aussi soit changer les instructions de démarage dans inittab et faire suivre d'un sudo init q, ou alors copier le directory d'installation là ou il devrait être, par exemple via la commande mv (move) ou via un cp -r

Comme ton server.py ne démarre pas, le système ne peut bien entendu pas fonctionner.

Avant d'aller plus en avant avec le debug matériel, met l'installation logicielle en ordre.
24/01/2016 Vieux  
 
  34 ans, Hainaut
 
Citation:
Posté par jcoenen Voir le message
Bon il semblerait que ton installation ne soit pas "standart".

Ou se trouve le directory raspVMC ?

Normalement loggé sur pi, après le download et unzip, un directory /home/pi/raspVMC-master est créé avec tout les logiciels a l'intérieur.

Le server est démarré a partir de ce directory (définition dans /etc/inittab), si tu as mis les logiciels ailleurs alors il faut aussi soit changer les instructions de démarage dans inittab et faire suivre d'un sudo init q, ou alors copier le directory d'installation là ou il devrait être, par exemple via la commande mv (move) ou via un cp -r

Comme ton server.py ne démarre pas, le système ne peut bien entendu pas fonctionner.

Avant d'aller plus en avant avec le debug matériel, met l'installation logicielle en ordre.
Je suis connecté en SSH et c'est l'utilisateur pi.

En gros j'ai fait:
- cd /usr/src (dois-je utiliser un autre répertoire ? --> /home/pi ?)
- wget https://github.com/jcoenencom/raspVM...ive/master.zip
- sudo unzip master.zip
- cd raspVMC-master
- sudo ./install.bash (car sinon j'ai des permissions denied)
- FHEM is not installed do you want it to be installed (Y/N) ? N
- 0 : /dev/ttyAMA0 Select the device connecting the VMC to the raspberry pi: 0
- Select the device connecting the ConfoSense to the raspberry pi: 1
- Use socat to define virtual port (fhem client) (Y/N): N
- debug level (2=config, 3=client, 8=frames, def=3): 8
- Use mysql database to store data sample (Y/N): N

Je vais essayer en me mettant dans /home/pi et non /usr/src.

Tadam lol

Contrôler sa VMC StorkAir / ComfoAir / zehnder via sa domotique

J'arrive pas à y croire

Deux erreurs que j'ai faite:
1). Je me suis trompé dans le sertisage des cables ethernet.
2). J'ai installé dans /usr/src alors qu'il faut mettre dans /home/pi


Merci beaucoup à toi jcoenen !!!

Maintenant j'ai plein de questions sur ma VMC.

Dernière modification par jipsie 24/01/2016 à 20h44.
24/01/2016 Vieux  
 
  56 ans, Liège
 
mwarf, un debug hyper fastoche

Et bien en voila encore une connectée !

Bon amusement, en ce qui concerne les "questions" VMC, ce n'est pas vraiment mon domaine, je fait juste la connexion avec le réseau et les systèmes de domotique.

VMC3.html permet de faire le reset du compteur des heures des filtres et de changer la température de confort.
24/01/2016 Vieux  
 
  34 ans, Hainaut
 
Ok je viens de reseter les filtres car ils étaient neufs:

Contrôler sa VMC StorkAir / ComfoAir / zehnder via sa domotique

Mes questions rapides:

- Je vois qu'il est indiqué WHR960, j'avais commandé une Comfo550D, c'est grave docteur?
- Rendement neuf 100% je suppose que c'est bien?
- Rendement extrait +/- 60% bien aussi?
- A combien faut t-il mettre la t° de confort?
- Mode:été... euh je sais que l'hiver est doux... mais ?
24/01/2016 Vieux  
 
  56 ans, Liège
 
Pareil içi, Comfo550D, et la VMC répond WHR960, c'est storkair VS Zendher, même boite, même firmware dans le contrôleur, l'appellation de la machine est la seule différence.


Les calculs de rendement sont fait sur les températures mesurée (in/out), il y a des kilomètres de discussions sur le sujet, trop fastidieux et technique pour moi ...

T° de confort, 12° pour un eskimoo (et même plus bas), içi elle est à 21° (cela dépend des personnes), cette température défini le mode été ou hiver, dans ton cas la TConfort étant à 12 °, et vu la température extérieure, le logiciel se dit qu'on est en été. Met donc celle-ci sur 21 et après un certain temps le mode va passer en hiver. Ceci agit aussi sur le bypass, qui s'ouvre et se ferme en fonction de pas mal de paramètres DONT la T° de confort, à 12° tu risque de bypasser l'échangeur et alors tu insuffle de l'air froid dans la maison.

Par contre 20% en vitesse de ventilateurs sur la première vitesse (1 = absent), c'est pas des masses, la VMC à bien été réglée par un spécialiste ???

Dernière modification par jcoenen 24/01/2016 à 22h17.
25/01/2016 Vieux  
 
  34 ans, Hainaut
 
Ok merci pour les infos.

J'ai réglé à 21.

Oui installation par un pro: J*D.
25/01/2016 Vieux  
 
  56 ans, Liège
 
Citation:
Posté par jipsie Voir le message
Ok merci pour les infos.

J'ai réglé à 21.

Oui installation par un pro: J*D.
OK alors elle doit être réglée au niveau du débit. Demande lui quant même quelle doit être la vitesse "normale" de fonctionnement (basse-moyenne ou haute).
25/01/2016 Vieux  
  France
 
Citation:
Posté par jipsie Voir le message
- Rendement neuf 100% je suppose que c'est bien?
- Rendement extrait +/- 60% bien aussi?
- A combien faut t-il mettre la t° de confort?
- Mode:été... euh je sais que l'hiver est doux... mais ?
Surprenant:
=>Les débit sont très différents entre l'entrée et la sortie.
même s'il est conseillé de mettre légèrement la maison en dépression ça me semble beaucoup.
=> un volume d'air non négligeable entre dans ta maison sans passer par la DF (il faut bien compenser la différence de débit). cet air est à la température extérieur et fait donc fortement chuter le rendement réel du système d'échange global.

Normalement le rendement entrant et sortant doivent être très proche.
26/01/2016 Vieux  
 
  Autre pays
 
Hi All,

I've just noticed jipsie's entries and as far as I could have understood, he uses same or very similar VMC unit and no Fhem client.
jipsie, do you use CCEase or not at all?
FYI, I can't get working together CCEase and CGI based pages (VMC*.html).
Could you please briefly confirm your setup as automatic translation really does suck?

My current plan is to connect CCEase directly to its port in VMC, rasbpi to RS232-PC port and disable CCEase socat client in raspbi.
As per drawing:
Contrôler sa VMC StorkAir / ComfoAir / zehnder via sa domotique
Is anybody able to confirm above VMC RS232-PC pinout?
27/01/2016 Vieux  
 
  56 ans, Liège
 
Hi Listhor, if I understand well your plan is to connect CCEASE and the raspi to the VMC via the ports available on the VMC, thus both CCEASE and raspi will talk at the same time to the VMC. This will not work.

Here is a summary of the different possible connections.

Contrôler sa VMC StorkAir / ComfoAir / zehnder via sa domotique


The CCEASE must be connected to the VMC VIA a raspi by design.

At home I have config No 5, and it has been working without trouble for a month, all VMC access are working, Web pages, FHEM, Comfosense, command line clients (mysql and knx scripts via cron), the VMC connected raspi is a model 2B, the Comfosense raspi is a B+

I have connected the raspi on the RJ45 of the VMC as I do not have the expansion board, some have reported that connecting to the db9 on the board was workable setup. But as soon as the CCEASE or Comfosense was connected on another VMC board port in parallel with the raspi, the raspi ceased to work. Which is normal.
27/01/2016 Vieux  
 
  Autre pays
 
Hi Jcoenen,

Maybe I'm not desperated but I would like to test every option. Since my VMC unit (WHR950) seems to be a different one (communication with CCEase almost ceases or reduces greatly communication to other clients, i.e. CGI and FHEM - no load on server.py) maybe those ports work differently?
I think there are 2 options, either:
- some firmware setting doesn't allow to communicate to other controlling unit on CCEase discovery (more likely),
- or hardware is slightly different...

As we discussed previously, my cabling and serial ports are fine as communication works when I use separately CCEase and other clients and same behavior is on both systems: Jessie and Wheezy.
Thus, the only part of this system responsible for malfunction must be on VMC unit's side... (?)
27/01/2016 Vieux  
  France
 
Jcoenen j'ai une petite question: Ton programme (client3.py par ex) vient lire (entre autres) les temps (en Heures ?) pour les différentes vitesse. Pour vitesse 3 j'ai toujours 0 pourquoi ? il m'arrive de passer en mode boost (donc par tranche de 30min) il m'arrive aussi de mettre en vitesse 3 sur le client HTML et de l'oublier pendant plusieurs heures.
Merci.

pour info:
"absent": 201,
"antigel": 0,
"bypass": 48,
"filtres": 2326,
"prechauffe": 3,
"vitesse1": 1075,
"vitesse2": 967,
"vitesse3": 0
27/01/2016 Vieux  
  36 ans, Autre pays
 
Salut a tout le monde.
J'ai un simple question: tout ca, œuvres avec le comfoAir160?
j'ai ecrit a le support de zender et ils m'ont repondu que cette machine n'as pas un port rs232, mais n'è pas vrai...:P
Merci pour le répond
27/01/2016 Vieux  
 
  56 ans, Liège
 
Citation:
Posté par listhor Voir le message
Hi Jcoenen,

Maybe I'm not desperated but I would like to test every option. Since my VMC unit (WHR950) seems to be a different one (communication with CCEase almost ceases or reduces greatly communication to other clients, i.e. CGI and FHEM - no load on server.py) maybe those ports work differently?
I think there are 2 options, either:
- some firmware setting doesn't allow to communicate to other controlling unit on CCEase discovery (more likely),
- or hardware is slightly different...

As we discussed previously, my cabling and serial ports are fine as communication works when I use separately CCEase and other clients and same behavior is on both systems: Jessie and Wheezy.


Thus, the only part of this system responsible for malfunction must be on VMC unit's side... (?)

Maybe I should do an investigation logging into your system (via a remote ssh).

What do you think ?
28/01/2016 Vieux  
 
  56 ans, Liège
 
Citation:
Posté par SpigoloN Voir le message
Jcoenen j'ai une petite question: Ton programme (client3.py par ex) vient lire (entre autres) les temps (en Heures ?) pour les différentes vitesse. Pour vitesse 3 j'ai toujours 0 pourquoi ? il m'arrive de passer en mode boost (donc par tranche de 30min) il m'arrive aussi de mettre en vitesse 3 sur le client HTML et de l'oublier pendant plusieurs heures.
Merci.

pour info:
"absent": 201,
"antigel": 0,
"bypass": 48,
"filtres": 2326,
"prechauffe": 3,
"vitesse1": 1075,
"vitesse2": 967,
"vitesse3": 0
Ah cr@ttes, en fait les vitesses dans la commande sont 1 pour absent, 2 pour basse, 3 pour moyenne et 4 pour haute, mais en lecture la VMC retourne absent, 1, 2 et 3

Je n'ai pas fait attention en encodant les valeurs lues et donc dans le json retourné, vitesse3 correspond a HAUTE (ou 4 dans la commande).

Faudra un jour que je normalise la chose.

Donc lecture
absent = absent
vitesse1 = low
vitesse2 = mid
vitesse3 = high

suis-je clair ? (pas certain quand je me relis ;)

Ah oui cette info est aussi disponible dans la page web, la boite (objet) en dessous des boutons de commande, cliques sur data - usage

Dernière modification par jcoenen 28/01/2016 à 00h13.
28/01/2016 Vieux  
 
  56 ans, Liège
 
Citation:
Posté par ingegnis Voir le message
Salut a tout le monde.
J'ai un simple question: tout ca, œuvres avec le comfoAir160?
j'ai ecrit a le support de zender et ils m'ont repondu que cette machine n'as pas un port rs232, mais n'è pas vrai...:P
Merci pour le répond
D'après CECI page 27 schematics, il y a un port rj45 donc ...

Et toujours sur zendher america, il y CECI le CA160 peut être piloté par un Comfosense, donc c'est compatible avec raspiVMC !

Donc zender dit des bêtises, il est possible de piloter la CA160 par raspiVMC.

RaspiVMC prend la place du CCEASE/COMFOSENSE donc toute machine qui permet la connexion d'un ccease/comfosense peut être pilotée par le programme.
28/01/2016 Vieux  
  36 ans, Autre pays
 
Citation:
Posté par jcoenen Voir le message
D'après CECI page 27 schematics, il y a un port rj45 donc ...

Et toujours sur zendher america, il y CECI le CA160 peut être piloté par un Comfosense, donc c'est compatible avec raspiVMC !

Donc zender dit des bêtises, il est possible de piloter la CA160 par raspiVMC.

RaspiVMC prend la place du CCEASE/COMFOSENSE donc toute machine qui permet la connexion d'un ccease/comfosense peut être pilotée par le programme.
Merci!
parce que le port RJ45 est occupé, je peux me connecter au port pour comfosense ou je mal compris?

ceci est la réponse qu'ils me donnaient. switch ils parlent est la physique avec 4 positions:
"Good afternoon.
If you have a building management system you could connect the switch live into the system and create a program.
Otherwise there is nothing we can offer.
I cannot access the link you have provided.
Kind regards"
28/01/2016 Vieux  
 
  56 ans, Liège
 
Citation:
Posté par ingegnis Voir le message
Merci!
parce que le port RJ45 est occupé, je peux me connecter au port pour comfosense ou je mal compris?

ceci est la réponse qu'ils me donnaient. switch ils parlent est la physique avec 4 positions:
"Good afternoon.
If you have a building management system you could connect the switch live into the system and create a program.
Otherwise there is nothing we can offer.
I cannot access the link you have provided.
Kind regards"
Normalement sur le port rj45 on connecte le Comfosense/CCease suivant le schéma (voir page 27). sur la 160 il y a une autre carte ou on peut le connecter et là on peut bancher le raspVMC.

Je suppose que le rj45 est occupé comme sur le schéma par la carte d'extention, ou il y a la possibilité de connecter le Comfosense


Un switch 4 position sur le rj45, cela ne correspond pas du tout au wiring diagram de la page 27 ???
Ce schéma ne montre pas de possibilité de mettre un switch pour commander les vitesse comme sur les modèles 350 et 550.
Page 53 sur 68 Première page - Résultats 1 à 20 sur 1 349 Page precedente 3435152 53 545563 Page suivante Dernière page - Résultats 1 341 à 1 349 sur 1 349


A lire également sur BricoZone...
Zehnder ou Storkair / whr ou confoD ? Par chevy3600 dans Plomberie, +3 13/06/2016
Storkair ConfoD luxe et domotique Par sebcbien dans VMC, PAC, Clim, +12 21/10/2013
VMC storkair Par lombsss dans VMC, PAC, Clim, +1 25/01/2013
VMC storkair comfod 350 Par sam_bech dans VMC, PAC, Clim, +16 22/01/2013
Où acheter VMC DF Zehnder/Storkair ? Par Lapilux dans VMC, PAC, Clim, +4 26/03/2012


Forum Domotique : Voir ce forum, Nouveautés, Actifs, Sans rép
Tout BricoZone : Page de garde, Dernieres 24h

Photos au hasard
Voir toutes nos photos


Pas encore membre de BricoZone ?!
Attention Pour participer, poser une Question ou Répondre : inscrivez vous !
Ceci vous permettra également de recevoir un email lors des réponses.
Mais même si vous ne voulez rien écrire : vous pourrez surveiller les forums et leurs nouveaux messages, et obtenir une vue rapide de tous les nouveaux messages depuis votre dernière visite !
Tout ceci est évidemment gratuit et rapide.

Visitez aussi : BricoZone France, nos Blogs. On aime Astel, JardiZone et InternetVista.
 
Connexion!
Identifiant
Mot de passe

Inscription - Oublié ?

Annuaire Pro

FT Chassis

Spécialiste des châssis PVC, bois et aluminium, portes et volets roulants.


DECOCHALET

Vente et placement d'abris de jardin, carports, garages, pergolas, boxes pour chevaux, ...


Tendance Habitat

Entreprise générale du bâtiment


La Vidange Loiseau S.A.

Débouchage, placement, raccordement et réparation des égouts.

Ajoutez votre société