- #401
Je n'ai pas eu de problème et livraison rapide de mon côté
type: tcp
host: 192.168.0.109 #IP-Adress of your ISGweb or ISGplus
port: 502
name: STIEBEL_ELTRON #Name for your Heat-Pump, needed if you have more than one (as i have)
close_comm_on_error: false
retry_on_empty: true
retries: 10
# INPUT-Entities - Only for Reading
- name: temp_ext
unique_id: temp_ext # Unique ID enables you to rename it and change Icon etc via UI
slave: 1
address: 506 #507 - 1 <== Meaning: In the Documentation the Modbus-Adress is 507, here i need to use 506 (always -1)
input_type: input
unit_of_measurement: °C
device_class: temperature
scale: 0.1
precision: 1
- name: temp_reelle_circuit-chauff1
unique_id: temp_reelle_circuit-chauff1
slave: 1
address: 507 #508 - 1
input_type: input
unit_of_measurement: °C
device_class: temperature
scale: 0.1
precision: 1
- name: temp_consigne_circuit-chauff1
unique_id: temp_consigne_circuit-chauff1
slave: 1
address: 509 #510 - 1
input_type: input
unit_of_measurement: °C
device_class: temperature
scale: 0.1
precision: 1
- name: temp_retour_relle
unique_id: temp_retour_relle
slave: 1
address: 515 #516 - 1
input_type: input
unit_of_measurement: °C
device_class: temperature
scale: 0.1
precision: 1
- name: temp_relle_tampon
unique_id: temp_relle_tampon
slave: 1
address: 517 #518 - 1
input_type: input
unit_of_measurement: °C
device_class: temperature
scale: 0.1
precision: 1
- name: temp_consigne_tampon
unique_id: temp_consigne_tampon
slave: 1
address: 518 #519 - 1
input_type: input
unit_of_measurement: °C
device_class: temperature
scale: 0.1
precision: 1
- name: temp_reelle_ECS
unique_id: temp_reelle_ECS
slave: 1
address: 521 #522 - 1
input_type: input
unit_of_measurement: °C
device_class: temperature
scale: 0.1
precision: 1
- name: temp_consigne_ECS
unique_id: temp_consigne_ECS
slave: 1
address: 522 #523 - 1
input_type: input
unit_of_measurement: °C
device_class: temperature
scale: 0.1
precision: 1
- name: etat_fonctionnement
unique_id: etat_fonctionnement
slave: 1
address: 2500 #2501 - 1
input_type: input
data_type: uint16
- name: etat_defaut
unique_id: etat_defaut
slave: 1
address: 2503 #2504 - 1
input_type: input
data_type: uint16
# HOLDING-Entities - Read AND Write possible
- name: mode_fonctionnement
unique_id: mode_fonctionnement
slave: 1
address: 1500 #1501 - 1
input_type: holding
data_type: uint16
- name: courbe_chauffe
unique_id: courbe_chauffe
slave: 1
address: 1503 #1504 - 1
input_type: holding
scale: 0.01
precision: 2
- name: temp_confort
unique_id: temp_confort
slave: 1
address: 1501 #1502 - 1
input_type: holding
unit_of_measurement: °C
device_class: temperature
scale: 0.1
precision: 1
- name: temp_eco
unique_id: temp_eco
slave: 1
address: 1502 #1503 - 1
input_type: holding
unit_of_measurement: °C
device_class: temperature
scale: 0.1
precision: 1
- name: temp_confort_ECS
unique_id: temp_confort_ECS
slave: 1
address: 1509 #1510 - 1
input_type: holding
unit_of_measurement: °C
device_class: temperature
scale: 0.1
precision: 1
- name: temp_eco_ECS
unique_id: temp_eco_ECS
slave: 1
address: 1510 #1511 - 1
input_type: holding
unit_of_measurement: °C
device_class: temperature
scale: 0.1
precision: 1
- name: "hub1"
close_comm_on_error: true
delay: 5
timeout: 5
type: tcp
modbus:
- name: hitachi
type: tcp
host: 192.168.1.60
port: 502
switches:
- name: pac_1000_unit_on_off
address: 1000
write_type: holding
command_on: 1
command_off: 0
verify:
input_type: holding
address: 1050
state_on: 1
state_off: 0
sensors:
- name: pac_1051_unit_mode
address: 1051
- name: pac_1052_circuit1_status
address: 1052
- name: pac_1053_circuit1_type_regul_chaud
address: 1053
- name: pac_1054_circuit1_type_regul_froid
address: 1054
- name: pac_1055_cons_temp_fixe_eau_chaud
unit_of_measurement: °C
address: 1055
- name: pac_1056_cons_temp_fixe_eau_froid
unit_of_measurement: °C
address: 1056
- name: pac_1057_circuit1_mode_eco_confort
address: 1057
- name: pac_1058_cons_temp_compensation_eco_chaud
unit_of_measurement: °C
address: 1058
- name: pac_1059_cons_temp_compensation_eco_froid
unit_of_measurement: °C
address: 1059
- name: pac_1062_cons_temp_thermostat
unit_of_measurement: °C
scale: 0.1
precision: 1
address: 1062
- name: pac_1063_temp_piece_thermostat
unit_of_measurement: °C
scale: 0.1
precision: 1
address: 1063
- name: pac_1090_unit_operational_status
address: 1090
- name: pac_1091_temp_exterieur
unit_of_measurement: °C
address: 1091
- name: pac_1092_temp_arrivee_eau
unit_of_measurement: °C
address: 1092
- name: pac_1093_temp_sortie_eau
unit_of_measurement: °C
address: 1093
- name: pac_1097_unit_power
unit_of_measurement: kWh
address: 1097
- name: pac_1201_temp_exterieur_moyenne
unit_of_measurement: °C
address: 1201
- name: pac_1212_frequence_inverter
unit_of_measurement: Hz
scale: 1
precision: 0
address: 1212
- name: pac_1214_intensite_compresseur
unit_of_measurement: A
scale: 1
precision: 0
address: 1214
- name: pac_1220_debit_eau
unit_of_measurement: m3/h
scale: 0.1
precision: 2
address: 1220
modbus:
- name: STIEBEL_ELTRON #Name for your Heat-Pump
type: tcp
host: 192.168.0.109 #IP-Adress of your ISGweb or ISGplus
port: 502
close_comm_on_error: false
retry_on_empty: true
retries: 10
sensors:
- name: temp_ext
unique_id: temp_ext # Unique ID enables you to rename it and change Icon etc via UI
address: 506 #507 - 1 <== Meaning: In the Documentation the Modbus-Adress is 507, here i need to use 506 (always -1)
slave: 1
input_type: input
unit_of_measurement: °C
device_class: temperature
scale: 0.1
precision: 1
Dans les graphiques de home wizard on montre l’intégration de la puissance sur base 5min. Graphique que j’ai réussi à reproduire dans grafana en utilisant la même logique. L’installation de influxdb s’est déroulé assez facilement, j’ai regardé une vidéo YouTube à ce sujet mais je n’ai pas rencontré de problèmes particuliers.Je n'ose plus poster ici de peur de me faire bannir pour squattage intempestif.
@guirikiki , j'ai installé mon P1 Meter vendredi dernier, mes panneaux et onduleurs produisent depuis fin août.
J'ai tout intégré mais je ne suis pas certain d'avoir bien tout renseigné dans le dashboard énergie natif de HA. J'ai pas crosschecké les données mais les shapes ne me semblent pas cohérents à ceux visibles dans l'App Homewizard.
J'ai aussi installé InfluxDb, mais pas moyen d'y connecté des sensors,.j'ai aussi installé Grafana, mais sans InfluxDb fonctionnel ça semble inutile.
Mon but était de m'assurer la conservation suffisamment longue de mes datas de conso/prod (je ne sais pas quelle est la péremption native), et de pouvoir d'après l'analyse des graph et données détaillées paramétrer ma PAC en fonction pour maximiser l'autoconsommation (ECS plus chaude mais chauffée uniquement durant les heures de production, tenter une approche similaire avec le tampon de mon chauffage sol)...
J'ai tenté de collaborer avec ChatGPT pour qu'il m'aide à configurer le tout, mais ces conseils sont obsolètes avec l'évolution massive de HA ces dernières années...
Faut vraiment que j'optimise cette production...
Voir la pièce jointe 132384
Dans les graphiques de home wizard on montre l’intégration de la puissance sur base 5min. Graphique que j’ai réussi à reproduire dans grafana en utilisant la même logique. L’installation de influxdb s’est déroulé assez facilement, j’ai regardé une vidéo YouTube à ce sujet mais je n’ai pas rencontré de problèmes particuliers.
Il faut aussi regarder quels sont les données du dongle que vous utilisez pour les graphiques natifs HA ? Avez vous une image ?